Part of Anesthesia Workstation
Main Body : High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of application : Adult and Child
Gas source : O2, N2O, Air: 0.28~0.6MPa
Flow meter : O2: 0.05~1.0L/min 1.1~10L/min
N20: 0.05~1.0L/min 1.1~10L/min
Air : 0.05~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply : 25~75L/min
Low oxygen pressure alarm : There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer : It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.
Respiratory Circuit : Working mode: all-close, semi-close, semi-open
APL: ≤12.5kPa
Respiratory Bellows : Bellows for adults, tidal volume range : 0~1500 ml
Bellows for children, tidal volume range : 0~300 ml
Anyone can be chosen for application
Part of Ventilator
Display Mode : High-definition 10.4” TFT color LCD screen display
Ventilation Mode : VCV, PCV, SIMV, MANUAL
Ventilation Functions : PEEP, SIGH, IP, IRV, Standby
Ventilation Parameters : Tidal volume 20~1600 ml
Rate 2~99 bpm
SIMV rate 2~20 bpm
I:E 4:1~1:8
Inspiratory trigger pressure : -10~20cmH2O
PEEP : 2~20cmH2O
Pressure Range : 5~60cmH2O
SIGH 1.5 times the inspiratory time (60-120 adjustable)
Inspiratory platform : 0~50%
Pressure control : 3~50cmH2O
Pressure slope : 1~10 gear
Parameters for ventilation monitoring : Expired tidal volume, Inhale tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous inspiratory rate, I/E, peak pressure of airway, average pressure, PEEP,inspiratory trigger pressure, Inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform,flow-volume loop, pressure-volume loop
Security Alarm System
Oxygen Concentration alarm : Upper limit setting range 21%~99%
Low limit setting range 18%~80%
Airway pressure alarm : upper limit setting range 5~60cmH2O
low limit setting range 0~50cmH2O
Per-minute ventilation volume alarmupper limit setting range 1~20L/min
low limit setting range 0~19L/min
Respiratory rate : upper limit setting range 10~99bpm
low limit setting range 0~50bpm
Tidal volume : upper limit setting range 10~1500ml
low limit setting range 0~1400ml
Sustained high-pressure alarm it will give alarm when stress have consistently been higher than 25cm H2O
Suffocation alarm
Power alarm
Battery voltage alarm
Intubation off alarm
Power : AC 220V 50Hz(UPS, Storage battery)
Mechanical Arms : (End-tidal CO2 monitoring)
(Specific interface of waste anesthesia gas)
*Items within brackets are optional.
We are Exporters and Suppliers of Anaesthesia Workstation Diamond at wholesale competitive prices from India.
Model No :
MAN APAW 121 Anaesthesia Workstation Diamond