Latest Event

Desco Medical India

Deluxe Scientific Surgico Pvt. Ltd.

An ISO 9001:2015, ISO 13485:2016 WHO GMP CE CERTIFIED CO.

Star Export House Company Approved by Govt of India

Moving Ahead With

Trust...

5 PARAMETER PATIENT MONITOR 12.1"

5 PARAMETER PATIENT MONITOR 12.1"

Model No : MIE IEPM 110

Type : MULTI PARAMETER MONITOR

Catalogue :

Short Description

5 PARAMETER PATIENT MONITOR 12.1" SUPPLIED BY DESCO MEDICAL INDIA

Product Description

5 Parameter Patient Monitor 12.1"  Supplied by Desco Medical India
 
Technical Specification:-
Quality Standards and Classification
CE, IS013485
SFDA                                : Class II b 
Anti-electroshock degree : Class I equipment
                                           (internal power supply)
TEMP/SpO 2 /NIBP         : BF
ECG/Resp                        : CF
 
Application Range
Adult / Paediatric / Neonatal / Medicine / Surgery / Operating Room / lCU / CCU
Display                              : 12.1" real color TFT screen
 
Environment
Operating environment :
Temperature                      : 0 ~40 C
Humidity                             : 15%~80%
Pressure                             : 86.0 kPa~106.0kPa
Transport and Storage environment :
Temperature                       : -20 ~55 C
Humidity                             : 10%~90%
Pressure                             : 86.0 kPa~106.0kPa
 
Power Requirements
AC                                      : 100 - 240V, 50Hz/60Hz
DC                                      : Built-in rechargeable battery
Battery                                : 11.1V 24wh Li-ion battery
2h operating after full charge
5min operating after low battery alarm
 
Dimension and Weight
Equipment                           : 340mm x 245mm x134 mm (about);
                                              2.798kg (about)
Package                              : 380mm x350 mm x 300mm; 4.598 kg (about)
 
Date Storage
Trend diagram/table            : 7x24h
N I BP review                       : 400 events
Wave review                        : 100min
Alarm review                        : 100 alarm events
Support drug concentration titration analysis
 
ECG
5 Leads                                : RA, LA, LL, RL, V
Lead mode                           : I, II, III, AVR, AVL, AVF, V
Gain                                      : x 1.25mm/mV,2.5mm/mV,
                                                5.0mm/mV, 10mm/mV,
                                                20mm/mV (error≥ 5%)
Sweep speed                        : 6.25mm/s,12.5mm/s,25mm/s,
                                                50mm/s (error ≥ ± 10%)
Bandwidth                             : Surgery 1~25 Hz
Monitor 0.5 ~40 Hz
Diagnostic 0.05 ~130 Hz
Sensitivity                              : >200 µ V P-P
CMRR: ≥112dB
Differential Input Impedance  : >5M
ohm Electrode Offset Potential  : ±300mV
Polarization Voltage               : ≥ ± 500mV
Input Impedance                    : ≥ 5 M
Calibration Voltage                : 1 mV ± 5%
 
ST Segment
ST Segment Range               : -2.0mV ~ +2.0mV
Accuracy                                : 0.02mV
 
NIBP
Method                                   :  Oscillometry
Measure mode                       : Manual, Auto, STAT
Measure interval in auto mode : 1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode : 5min
Pulse rate range                       : 40 ~240bpm
Measure & alarm range            :             Adult
                                                    SYS  40~280mmHg
                                                    DIA  10~220mmHg
                                                    MEAN  20~240mmHg
                                                             Paediatric
                                                    SYS  40~220mmHg
                                                     DIA  10~160mmHg
                                                   MEAN 20~170mmHg
                                                               Neonatal
                                                    SYS  40~135mmHg
                                                     DIA  10~100mmHg
                                                   MEAN  20~110mmHg
Static pressure measurement
Range                          : 0 ~ 300mmHg
Accuracy                      : ± 3mmHg
Resolution                    : 1 mmHg Accuracy:
Max. Mean Error          : ± 5mmHg
Max. Standard Deviation  : 8mmHg
Overpressure protection   :
  Adult   300mmHg
  Paediatric  240mmHg
  Neonatal  150mmHg
Sp02
Measurement range         : 0~100%
Resolution                        : 1%
Accuracy                          :  70%~100% ± 2%
                                            40%~69% ± 3%
 
Pulse Rate
Measure/alarm range       : 20 ~300bpm
Resolution                        : 1 bpm
Accuracy                          : ± 3bpm
 
RESP
Method                             : impedance between RA-LL
Resp Impedance range    : 0.3 - 3 ?
Base Impedance range    : 200 Q - 4000 ?
Bandwidth                        : 0.3~2.5Hz
Gain                                  : x 0.25, x 0.5, x 1, x 2, x 4
Resp rate:
Measurement Range
Adult 0~120BrPM
Neonatal/Paediatric 0~150BrPM
Resolution: 1BrPM
Accuracy                          : 7~150BrPM (± 2BrPM)
                                            0 - 6BrPM (unspecified)
Apnea Alarm                    : 10 ~40s
 
TEMP
Channel 2
Measure & alarm range    : 0~50 °C
Resolution                         : 0.1 °C
Accuracy (no sensor)        : ±0.1 C (0~50 °C)
 
Standard accessories
• NIBP cuff & tube
• ECG cable & electrodes
• SpO2 sensor
• TEMP probe
• Lithium-ion battery
• Power cable
• Operator's manual
We are Exporters and Suppliers of 5 Parameter Patient Monitor 12.1" at wholesale competitive prices from India.  
 
Model No :
MIE IEPM 110           5 Parameter Patient Monitor 12.1"